• Samurai Solar UPS

Specifications

  • Solar UPS function (optional/scalable)
  • On-line “double conversion” technology (VFI)
  • High efficiency > 94%
  • Cold start function
  • Output power factor 0.9
  • Output short circuit and overload protection
  • Emergency power off (EPO)
  • Big graphic LCD screen
  • Automatic battery test
  • High capacity charging current in the battery
  • Temperature compensated battery charging
  • 512 events memory (more than 46000 alarms)
  • 2 serial ports RS232 and dry contact control via Teamviewer
  • Split bypass input
  • Internal batteries up to 80kVA (6-12kWh)
  • Very small footprint
  • Up to 8 units can be connected in parallel
  • Relay contacts (programmable)
  • Backfeed protection
  • EFM – Energy Flow Manager

Application

Samurai Solar UPS
Samurai Solar UPS
Samurai Solar UPS

One UPS, multiple choices

Samurai Solar UPS

Traditional UPS (Solar UPS)

Samurai Solar UPS

Traditional UPS (Solar UPS)
on-grid

Samurai Solar UPS

Traditional UPS (Solar UPS)
off-grid

Samurai Solar UPS

Options

  • SNMP card
  • MODBUS adapters

Technical specification

Samurai Power Solar UPS VFI 10k TS VFI 15k TS VFI 20k TS VFI 30k TS VFI 40k TS VFI 60k TS VFI 80k TS VFI 100k TS VFI 120k TS VFI 160k TS VFI 200k
TS
Power (kVA) 10 15 20 30 40 60 80 100 120 160 200
Input
Voltage 380 / 400 / 415 V AC 3 phase +N, +/- 20% (415 V AC +15% -25%)
Frequency range 50 / 60 Hz selectable, +/- 10 Hz
Power factor 0.99
Harmonic distortion (THDi)
Additional bypass input Yes
Bypass voltage range 380 / 400 / 415 V AC 3 phase +N, +/- 10%
Solar charge controller Yes – Solar UPS function
Output
Power factor 0.9
Power (kW) 9 13.5 18 27 36 54 72 90 108 144 180
Voltage regulation 380 / 400 / 415 V AC 3 phase +N, +/- 1% (220 / 230 / 240 V AC for 10 ~ 30 kVA)
Frequency 50 Hz or 60 Hz adjustable
Frequency regulation Line synchronized +/- 2%, battery mode +/- 0,1% adjustable
Efficiency Up to 94%
Crest factor 3:1
Overload protection 100 ~ 125% 10 min / 125 ~ 150% 60 sec
Additional protection Short circuit, voltage and current range
Harmonic distortion (THD) < 3% at 100% linear load
Battery
Type VRLA AGM / GEL or other types
Nominal voltage +/- 360 V DC (2x 30 ~ 12 V DC)
Float or end of discharge DC voltage +/- 405 V DC, +/- 300 V DC
Battery Internal External
Protection Overcharging, battery fuses, temperature compensation
Automatic test Daily, weekly (adjustable)
General
Standard EMC / LVD / EMI – EN62040 – 1/2, EN60950
User interface Multi language graphical LCD
LCD information Phase to phase voltage, phase to neutral voltage/current, power, frequency, crest factor, T °, error code
Advanced Auto diagnostic, different maintenance alarms and calibration through RS232
Communication 2x RS232 ports, 4 dry contacts (in option 8 dry contacts)
Input Generator contact and emergency power off
Genset kit User programmable
Software Management software
Alarm 200 events (time and date) / option 500 events
Protection Over-temperature, over-current, over-temperature alarm
Temperature range 0 °C ~ 40 °C
Protection degree IP20 (IP54 optional)
Humidity / Altitude 90% max without condensation / <1000m
Audible noise ≤ 56 dB ≤ 61 dB ≤ 64 dB ≤ 67 dB
Weight (kg) 86 92 98 175 182 196 218 259 480
Dimensions W x D x H (mm) 398 x 812 x 1037 513 x 852 x 1437 882 x 763 x 1797
Solar UPS controller
Power 5/10 kW (up to 10 units parallel)
MPPT input 270 ~ 640 V DC
Input min/max Voc 200 V DC / 750 V DC
Efficiency ≥ 97%
Communication RS232, 4 dry contacts, EPO, multi language graphical LCD
Dimensions W x D x H (mm) / weight (kg) 500 x 450 x 3U / 13 kg (5 kW), 17 kg (10k W)