• Samurai TC 1–3 kVA

Specifications

  • On-line “double conversion” technology (VFI)
  • DSP (digital signal processor) technology
  • Internal static and manual bypass
  • Input power factor up to 0.99
  • Battery (DC) cold start
  • Site wiring fault indication
  • Self testing at UPS start-up
  • RJ45/11 network protection
  • Intelligent management through RS232 & USB
  • For extended backup time check VFI 1000-3000 TCL series (external batteries)

Application

Samurai TC 1–3 kVA
Samurai TC 1–3 kVA
Samurai TC 1–3 kVA

Samurai VFI 1–3 kVA TC UPS systems is a line of advanced, true on-line UPSs supplying clean, reliable and regulated AC power perfectly adapted to your needs.

Samurai VFI 1–3 kVA TC is an advanced, true on-line Uninterruptible Power Supply (UPS) providing reliable, regu­lated and stable voltage to any type of load. It is available in models supplying 1, 2 and 3 kVA.

Samurai TC 1–3 kVA

Options

  • SNMP adapter
  • Relay card (dry contacts)
  • External maintenance bypass
  • Additional / external battery packs

Technical specification

Samurai Power VFI TC 1000 2000 3000
Power (VA / Watt) 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W
Input
Nominal voltage 220 / 230 / 240 V AC
Operating voltage range 115 ~ 295 V AC
Operating frequency range 50 / 60 Hz ± 10% (auto sensing)
Power factor ≥ 0.99
Output
Output voltage >200 / 208 / 220 / 230 / 240 V AC ± 1%
Output frequency Synchronized with the utility on AC mode; 50/60 Hz ± 0,2% on battery mode
Harmonic distortion (THD) < 3% at 100% linear load
Crest factor 3:1 (max)
Voltage regulation +/- 2% at nominal voltage
Efficiency at 75-100% load > 86% (online), > 94% (high efficiency mode)
Battery
DC voltage 24 V DC 48 V DC 72 V DC
Battery type & number 12 V / 7 Ah x2 12 V / 7 Ah x4 12 V / 7 Ah x6
Backup time 50% load ≥ 5 min (Standard), long run unit depends on the capacity of external batteries
Charge current 4 A
Protection
RJ11/45 protection Yes
Input / Output Overvoltage, short-circuit, battery deep discharge, thermal protection
Overload in battery mode 101 ~ 150%: 30 sec, > 150%: 30 msec, before inverter cut off
Overload in AC mode 101 ~ 150%: 30 sec, > 150%: 30 msec before switching to bypass
Alarms – informations
Audible Battery backup, battery low, overload status, fault status
LED Mains, inverter, bypass, fault, battery level
LCD Input and output voltage, load %, battery voltage, errors codes
Environmental
Operating / Storage temperature 0 ~ 40 °C / -25 to 55 °C
Humidity range / Altitude 0 – 95% (non-condensing) / < 1500 m
Audible noise at 1m < 50 dB
Interface
Standard RS232 / USB (software included)
Optional SNMP / Relay card (dry contacts)
Dimensions
Weight (kg) 10.2 19.5 24
Dimensions W x D x H (mm) 144 x 405 x 215 191 x 455 x 332 191 x 455 x 332
Standard
EMC IEC/EN62040-2, IEC/61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
Safety IEC/EN62040-1, IEC/EN60950-1

We are always ready to help you!