Project Description

  • Samurai VFI 10–40 kVA TC

Specifications

  • On-line “double conversion” technology (VFI)
  • Parallel redundancy On-line UPS (up to 4 units)
  • Input power factor up to 0.99 (PFC technology)
  • DSP (Digital Signal Processor) technology
  • Common battery string for parallel units
  • IGBT technology (rectifier and inverter)
  • Internal static and manual bypass
  • 16/18/20/40 pcs 12V batteries per string (adjustable)
  • ECO-mode for energy-saving
  • Intelligent charging management
  • Self-test during UPS start-up
  • Internal and external batteries
  • Unbalanced load acceptable
  • Wide input voltage range
  • Battery (DC) cold start
  • LCD-LED double display with audible/visible alarms
  • ES485 and USB ports, dry contacts
  • EPO (Emergency Power Off)
  • Backfeed protection

Application

Samurai VFI 10–40 kVA TC
Samurai VFI 10–40 kVA TC
Samurai VFI 10–40 kVA TC

Price-performance Ratio

The VFI 10–40 kVA TC series is our best “price-performance ratio” 3/3 phase UPS. Based on our modular UPS technology, we are able to offer extremely small UPS 10-30kVA solutions. A combination of our modular based UPS with a special DC/DC converter, the VFI TC UPS can work with a battery voltage of only 192 to 240 V DC (adjustable). It allows to reduce space, batteries and price.

Samurai VFI 10–40 kVA TC

Options

  • SNMP card
  • Relay card
  • External maintenance bypass
  • Galvanic isolation transformer

Technical specification

Samurai Power
VFI TC 3/3
10000200003000040000
Power (VA / Watt)10 kVA / 9 kW20 kVA / 18 kW30 kVA / 27 kW40 kVA / 36 kW
Input
Nominal voltage380 / 400 / 415 V AC (3 ph+N+PE)
Maximum voltage208 ~ 478 V AC
Frequency range43 ~ 65 Hz
Power factor0.99
Harmonic distortion (THDi)< 3% (at 100% non-linear load)
Bypass voltage range-45%, +15%
Bypass frequency range+/- 10%
Output
Voltage regulation380 / 400 / 415 V +/- 1% at nominal load
Frequency50 / 60 Hz +/- 0,1 Hz
Efficiency at 75 – 100% load93% (AC mode) / 94% (battery mode) / 97% (ECO mode)
Harmonic distortion (THD)< 2% linear load, < 5% non-linear load
BypassInternal static (automatic) and manual bypass / External bypass optional
Transfer timeMains to battery: 0 msec, mains to bypass: 0 msec
Crest factor3:1
Battery
VoltageAdjustable (192 / 216 / 240 / 480 V DC)
ECO mode1,35 A2,7 A2,7 A10 A
Protection
Input / outputOvervoltage, short-circuit, battery deep discharge, thermal protection
Overload≤ 110%: 60 min, ≤ 125%: 10 min, ≤ 150%: 1 min, > 150: switch to bypass mode
Alarms – informations
Audible alarmLine failure, battery low, bypass-overload status, fault status
LEDLine- / backup- / ECO- / bypass-mode, battery low / bad / disconnected, overload, fault
LCDVoltage / frequency, load %, battery voltage/runtime
Standard
SafetyIEC / EN62040-1, IEC/EN60950-1
EMCIEC / EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC6100-4-4, IEC6100-4-5, IEC61000-4-8
Protection classIP20
Interface
StandardUSB, dry contacts, intelligent slot, parallel port RS485, RS232, EPO
OptionalSNMP / Relay card
Dimensions
Weight – without batteries (kg)42454567
W x D x H (mm)250 x 828 x 868
Environment
Temperature / Humidity0 ~ 40 ˚C / 0 ~ 95% (non-condensing)
Audible noise at 1m< 55dB< 58 dB
Interface
StandardRS232, USB, EPO, intelligent slot
OptionalSNMP, relay card

We are always ready to help you!

call us
write us
return to products